起订量:
高压冷冻式空气干燥机
免费会员
Powerful cooling systems
The refrigeration dryers in HP series units feature powerful cooling systems. These include a high quality refrigerant compressor, generously-dimensioned heat exchanger surfaces, as well as cleverly designed cooling air flow. This combination therefore ensures dependable operation even at high temperatures and guarantees stable pressure dew points at all times.
Flow optimized piping
The smaller the pressure differential within a dryer, the more efficient its performance. All HP dryers operate with exceptionally low pressure differential values thanks to quality, flow optimized stainless steel piping.
HIGH EFFICIENT DRAIN - High pressure TYPE
The 40bar HP Series dryer is equipped with a high pressure DRAIN ensures even more efficient condensate removal without any pressure loss and also saves energy. The electronic condensate drain is optional for the 50 bar version.
Technical Specification
Model | Air Connection | Capacity m³/min | Power Supply V/Ph/Hz | Absorbed Power (kW) | Dimension mm | Weight (kg) | |||
m³/min | CFM | L | W | H | |||||
RSLF-12-HP | Rc1/2" | 1.2 | 42 | 230/1/50 | 0.26 | 600 | 310 | 500 | 35 |
RSLF-15-HP | Rc1/2" | 1.5 | 53 | 230/1/50 | 0.28 | 600 | 310 | 500 | 35 |
RSLF-18-HP | Rc1/2" | 1.8 | 64 | 230/1/50 | 0.30 | 600 | 310 | 500 | 35 |
RSLF-24-HP | Rc3/4" | 2.4 | 85 | 230/1/50 | 0.46 | 750 | 360 | 550 | 50 |
RSLF-30-HP | Rc3/4" | 3.0 | 106 | 230/1/50 | 0.50 | 750 | 360 | 550 | 50 |
RSLF-36-HP | Rc3/4" | 3.6 | 127 | 230/1/50 | 0.53 | 750 | 360 | 550 | 55 |
RSLF-40-HP | Rc3/4" | 4.0 | 141 | 230/1/50 | 0.55 | 750 | 360 | 550 | 55 |
RSLF-60-HP | Rc1-1/4" | 6.0 | 212 | 230/1/50 | 0.80 | 750 | 550 | 880 | 80 |
RSLF-80-HP | Rc1-1/4" | 8.0 | 282 | 230/1/50 | 0.85 | 750 | 550 | 880 | 80 |
RSLF-90-HP | Rc1-1/4" | 9.0 | 318 | 230/1/50 | 0.90 | 750 | 550 | 880 | 80 |
RSLF-100-HP | Rc1-1/4" | 10 | 353 | 230/1/50 | 1.10 | 750 | 550 | 880 | 80 |
RSLF-120-HP | Rc1-1/4" | 12 | 424 | 230/1/50 | 1.22 | 750 | 550 | 880 | 80 |
RSLF-150-HP | Rc1-1/4" | 15 | 530 | 230/1/50 | 2.10 | 1100 | 860 | 1200 | 150 |
RSLF-200-HP | Rc1-1/4" | 20 | 706 | 230/1/50 | 2.30 | 1100 | 860 | 1200 | 150 |
RSLF-250-HP | Rc2-1/2" | 25 | 883 | 400/3/50 | 2.80 | 1100 | 900 | 1550 | 270 |
RSLF-300-HP | Rc2-1/2" | 30 | 1059 | 400/3/50 | 2.90 | 1100 | 900 | 1550 | 270 |
RSLF-350-HP | Rc2-1/2" | 35 | 1236 | 400/3/50 | 3.10 | 1100 | 900 | 1550 | 300 |
RSLF-400-HP | Rc2-1/2" | 40 | 1412 | 400/3/50 | 4.20 | 1100 | 900 | 1550 | 350 |
RSLF-500-HP | Rc2-1/2" | 50 | 1766 | 400/3/50 | 4.56 | 1100 | 900 | 1550 | 470 |
RSLF-600-HP | DN80 | 60 | 2119 | 400/3/50 | 5.60 | 1450 | 1130 | 1650 | 550 |
RSLF-700-HP | DN80 | 70 | 2472 | 400/3/50 | 5.80 | 1450 | 1130 | 1650 | 570 |
RSLF-800-HP | DN80 | 80 | 2825 | 400/3/50 | 5.94 | 1450 | 1130 | 1650 | 600 |
Rated Conditions | |
Working pressure: 4.0Mpag / 580psig | |
Inlet temp: 38℃ / 100 ℉ | |
Ambient temp: 38 ℃ / 100 ℉ | |
Working Range | |
Max. working pressure: 4.5Mpag / 653psig | |
Max. inlet temperature: 60℃ / 140 ℉ | |
Max. ambient temperature: 50℃ / 122 ℉ | |
Min. ambient temperature: 5℃ / 41 ℉ | |
Avaliable Options | |
Different power supply | |
Water cooling version from model 150 and above |
Correction Factors
Actual Capacity (m³/min) = Nominal Capacity × KA × KB × KC
Working Pressure (KA) | Mpag | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | 4.5 |
psig | 290 | 363 | 435 | 508 | 580 | 653 | |
CFP | 0.93 | 0.96 | 0.97 | 0.99 | 1.00 | 1.01 |
Inlet Temperature (KB) | ℃ | 30 | 32 | 38 | 43 | 49 | 54 | 60 |
℉ | 86 | 90 | 100 | 110 | 120 | 130 | 140 | |
CFT | 1.27 | 1.18 | 1.00 | 0.87 | 0.76 | 0.68 | 0.61 |
Ambient Temperature (KC) | ℃ | 16 | 21 | 27 | 32 | 38 | 43 | 49 | 50 |
℉ | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 122 | |
CFT | 1.15 | 1.12 | 1.08 | 1.04 | 1.00 | 0.95 | 0.90 | 0.89 |