品牌
生产厂家厂商性质
上海市所在地
大鼠β2-微球蛋白(β2M)ELISA Kit
面议二噁英检测试剂盒美国ABRaxis*
面议人脂肪细胞型脂肪酸结合蛋白(FABP4) ELISA Kit
面议人B-细胞激活因子(BAFF)检测试剂盒
面议人细胞因子信号转导抑制因子3(SOCS3) ELISA Kit
面议G2(IgG2)检测试剂盒
面议人1(KLK1) ELISA Kit
面议大鼠*释放激素受体(GnRHR) ELISA Kit
面议小鼠转运蛋白1(TNPO1) ELISA Kit
面议大鼠AMP激活蛋白激酶β1(PRKAβ1) ELISA Kit
面议人黑素瘤细胞黏附分子(MCAM) ELISA Kit
面议人磷脂酰肌醇蛋白聚糖3(GPC3) ELISA Kit
面议小鼠谷氨酸脱氢酶(GLDH)ELISA试剂盒FOR RESEARCH USE ONLY
Drug Names
Generic Name:小鼠谷氨酸脱氢酶(GLDH)ELISA试剂盒
This kit can be used for determination of serum, plasma and liquid samples Organization Content.
The experimental principle:
The product levels were measured in samples of the kit by double antibody sandwichmethod. The product with the purified antibody coated microtiter plate, made of solid phase antibody, to package is the product antigen monoclonal antibodies are then added to the micropores, the product and then with HRP labeled antibody binding, the formation of antibody - antigen - antibody complex enzyme label, after thorough washing with TMB chromogenic substrate. TMB in the HRP enzyme catalytic conversion into the blue, and in the action of acid into the final yellow. This product is positively related to the depth of color and in the samples. Instrument measured absorbance in the 450nm wavelength with ELISA (OD), the product concentration in the samples was calculated by standard curve.
Materials provided with the kit
Materials provided with the kit 48determinations 96 determinations Storage
User manual 1 1
Closure plate membrane 2 2
Sealed bags 1 1
Microelisa stripplate 1 1 2-8℃
Standard:360ng/L 0.5ml×1 bottle 0.5ml×1 bottle 2-8℃
Standard diluent 1.5ml×1 bottle 1.5ml×1 bottle 2-8℃
HRP-Conjugate reagent 3ml×1 bottle 6ml×1 bottle 2-8℃
Sample diluent 3ml×1 bottle 6ml×1 bottle 2-8℃
Chromogen Solution A 3ml×1 bottle 6ml×1 bottle 2-8℃
Chromogen Solution B 3ml×1 bottle 6ml×1 bottle 2-8℃
Stop Solution 3ml×1 bottle 6ml×1 bottle 2-8℃
wash solution (20ml×20 fold)
×1bottle (20ml×30 fold)
×1bottle 2-8℃
Specimen requirements
1.serum- coagulation at room temperature 10-20 mins,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.
2.plasma-use suited EDTA or citrate plasma as an anticoagulant,mix 10-20 mins ,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.
3.Urine-collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again. The Operation of Hydrothorax and cerebrospinal fluid Reference to it.
4.cell culture supernatant-detect secretory components, collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant,detect the composition of cells, Dilut cell suspension with PBS(PH7.2-7.4), Cell concentration reached 1 million / ml, repeated freeze-thaw cycles, damage cells and release of intracellular components, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.
5.Tissue samples- After cutting samples, check the weight,add PBS(PH7.2-7.4), Rapidly frozen with liquid nitrogen, maintain samples at 2-8℃ after melting,add PBS(PH7.4), Homogenized by hand or Grinders, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant.
6.extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
7.Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
Assay procedure
1.Dilute and add sample to Standard: set 10 Standard wells on the ELISA plates coated, add Standard 100μl to the first and the second well, then add Standard dilution 50μl to the first and the second well, mix; take out 100μl form the first and the second well then add it to the third and the forth well separay. then add Standard dilution 50μl to the third and the forth well ,mix ; then take out 50μl from the third and the forth well discard, add 50μl to the fifth and the sixth well ,then add Standard dilution 50μl to the fifth and the sixth well, mix ; take out 50μl from the fifth and the sixth well and add to the seventh and the eighth well, then add Standard dilution 50μl to the seventh and the eighth well ,mix ; take out 50μl from the seventh and the eighth well and add to the ninth and the tenth well, add Standard dilution 50μl to the ninth and the tenth well, mix , take out 50μl from the ninth and the tenth well discard(add Sample 50μl to each well after Diluting ,(density: 240ng/L,160ng/L ,80ng/L,40ng/L, 20ng/L)
2.add sample:Set blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
4.Configurate liquid: 30-fold (or 20-fold)wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
5.washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme:Add HRP-Conjugate reagent 50μl to each well, except blank well.
7.incubate:Operation with 3.
8.washing:Operation with 5.
9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
11.assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
Important notes
1.The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
2.washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
3.add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 mins, if the number of sample is much , recommend to use Volley .
4.if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
5.Closure plate membrane only limits the disposable use, to avoid cross-contamination.
6.The substrate evade the light preservation.
7.Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
8.All samples, washing buffer and each kind of reject should according to infective material process.
9.Do not mix reagents with those from other lots.
Calculate:
Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.
Storage and validity
1.Storage: 2-8℃.
2.validity: six months.
其它产品
1073925 Ni-NTA Superflow (8 x 500 ml),cus,G
9010931 BGR Greifer P7 (alt)
9010858 BGR DT-Abstreifer 8-fach P7xxx D
931036 QIAsymphony Virus/Bact Mini Kit (192)
133248 NeXtalStock Sodium succinate pH6.5 (200)
330603 RT² SYBR Green FAST Mastermix (24)
929608 QX Pro Separation Buffer (40 ml)
5000-1415 Knob RB671CSKWL Matte, VTX2
5000-1408 Cable Shielded 1/17HP, VTX2
L2170 hc2 CT/GC HC2 DNA Test PI (CD-ROM)
L1971 Rotary Shaker User's Manual
9240705 O-ring Kit, Capper, Spindle, AP
9240693 Actril Sterilant & Test Strips, AP
9243653 Comprehen Valid., Other Extraction Sys """The Comprehensive Validation Support plan specific to a laboratory's needs will incorporate all of the requirements for the internal validation guidelines from the FBI's Quality Assurance Standards (QAS).
The Comprehensive Validation Support service includes all travel and labor charges for up to 20 days by the QIAGEN Validation Team. Typically, one week will be required to extract, quantify, and amplify the validation study samples and may require multiple individuals. Usually, two weeks is required to analyze the data and one week to write the final report. The expected time period to complete the Comprehensive Validation is six weeks. The actual time may vary depending on resource availability, including laboratory time dedicated to validation activities.
Lab Work – The QIAGEN specialist(s) will travel to the laboratory to conduct the on-site validation lab work. The QIAGEN specialist team will perform and complete all extractions, quantifications, amplfications, and capillary electrophoresis. The laboratory is responsible for providing systems/protocols that may be needed (generally laboratory SOPs, ex. interpretation guidelines). Additionally, the laboratory staff may be required to provide additional data needed for interpretation (ex. quantification/amplification/CE results) during the data review phase of the validation.
Once the final scope of the validation is determined, QIAGEN will provide a quote for all consumables required for the validation. Non-QIAGEN chemistry and accessories are not included and should be purchased to cover the validation experimental design including qPCR, STR, NIST standards, required samples types (blood, semen, buccal samples) and required substrates (swabs, materials, etc). The Customer is expected to have all materials on-hand 1 week prior to the validation start date.
Data Analysis – The Comprehensive Validation Support plan encompasses data collection (quants, amps, CE) during the on-site visit. The laboratory may be responsible for sharing (typically electronically via ) any validation data requested after the on-site visit. A QIAGEN specialist will complete all of the data analysis produced from the validation study design. This includes qPCR (quant) and STR (amp) analysis and linkage to starting samples.
Validation data CD/flashdrive – QIAGEN will review the validation data and draft a validation summary document, ensuring compliance with the FBI's QAS requirements/standards. QIAGEN will send validation data in an electronic format (/CD/flashdrive) to the laboratory. The laboratory is responsible for final compilation, any format change preferences, review and signoff of the validation report. The documentation provided by QIAGEN will aide in demonstrating compliance with all accreditation guidelines during laboratory audits. Should a hard copy of the validation study be preferred, the laboratory is required to specify prior to the onset of the validation.
Post-validation QIAGEN-to-Laboratory Transfer – Following completion of the validation and generation of the draft validation summary document, a designated member of the QIAGEN validation team will review the validation with the Lab Manager and the Technical Leader. Following sign off on the validation report, training of the laboratory DNA staff will occur. Refer to the Post-validation Competency Training for additional information. """
386516 Investigator STR GO! Lysis Buffer (200)
208256 QuantiNova Probe PCR Kit (2500)
208254 QuantiNova Probe PCR Kit (500)
180984 GeneRead Adapter I Set 12plex (72)
614035 careHPV Test, SFDA (96-test)
282605 virotype Influenza A RT-PCR Kit (96)
272703 pigtype PRRSV Ab (5)
273003 pigtype Salmonella Ab (5)
280377 virotype BVDV RT-PCR Kit (480)
9018462 Marker Kit, QC tool, QX
800372 Shipping, Postage, Packaging (express)
800373 Data Carrier
9019521 ZLV ADAPTER KIT M&N 8 STRIP
9019595 ZLV Bush, tip stripper, Cx8
9019935 Cable harness, X-axis 8 core, CQX
9020596 Tape Foam,045X750 Double Stick,DML 3000
9017843 Tool, cable, communication, RS232, QIAC
9013401 Cable set, cooling system, 90/120
9234873 ZLVPipetting Station for 2 microtit.
9013395 Tip disposal bags
9013391 Tubing set, PVC, BR9604
9013268 Cable, card-X to solenoid valve, 24V
9013222 Holder, tube, STS, single, 11 ml (30), 0
9013204 Transportation kit, BR8000
9011759 Reagent holder, 4-tube 13ml Holder for accommodating 4 microcentrifuge tubes (13 ml) on the worktable; must be used with the reagent holder tray
9011672 Reader Abdeckung spez. GSG (9194)
132605 NeXtal Stock Sodium ac. H2O (50) 1.6M Sodium acetate trihydrate - 50mL (4 x 12,5 ml tube)
800141 Investigation grade sequencing, w/ prep "Single-stranded sequencing of an unknown sequence
QIAGEN DNA template preparation
Design and synthesis of walking primers
Data assembly and sequence alignment
Accuracy >99%"
767134 PAXgene Tissue DNA Kit (50)
929605 QX Mineral Oil (50 ml)
330513 RT² SYBR Green Fluor qPCR Mastermix (24)
330502 RT² SYBR Green qPCR Mastermix (12)
330401 RT² First Strand Kit (12)
9010813 BGR Stirrer PK80
69506 DNeasy Blood & Tissue Kit (250) 250 DNeasy Spin Columns, QIAGEN Proteinase K, Buffers, Collection Tubes (2 ml)
63204 DyeEx 2.0 Spin Kit (50) 50 DyeEx Spin Columns, Collection Tubes (2 ml)
211392 Internal Control DNA (High conc.)
9012755 Set, Tubing, Washer, P3
9010126 Washer boat
979015 MOTT 16S Primer 1 for Sequencing
979010 PyroMark Vacuum Prep Filter Probe (100) Re-usable filter probes for PyroMark Vacuum Workstation Q96 and Q24.
59720 EpiTect Fast 96 DNA Bisulfite Kit
9002245 QIAcube(220-240v) Promo, PrioPLUS QIAcube (220-240V) Promo Priority includes the QIAcube instrument +promo iPad, installation and extended warranty. Installation covers hardware and software installation of system and provides user with introductory training. Priority package extends warranty period of the system to 3 years. One preventive maintenance visit is included for each year of the warranty; 3 preventive maintenance visits in total. Service package includes all parts, labor and travel costs with a service response time of 48 hours (2 working days). Performance of the installation and service visits are documented on a GMP/GLP-compliant Field Service documents.
9002198 RGQ 5plex HRM, PC, PrioPLUS, no PM "RGQ 5plex, HRM, PC Instrument
Installation of RGQ 5plex HRM & Introductory training
Warranty extension to 3 yrs
Repair Center service, response 7-10 days
Loaner available in 2 days*
No preventive Maintenance
Priority service provision over non-contract customers
Documented installation & repair report
Unlimited number of repair service
All cost covered (Shipping, labor, parts)"
9002197 RGQ 5plex, PC, PrioPLUS, basic, no PM "RGQ 5plex, PC Instrument
Installation of RGQ 2plex & Introductory training
Warranty extension to 3 yrs
Repair Center service, response 7-10 days
No Loaner available
No Preventive Maintenance
Priority service provision over non-contract customers
Documented installation & repair report
Unlimited number of repair service
All cost covered (Shipping, labor, parts)"
9012718 Pipetting Position (raised platform)
9002042 Rotor-Gene Q MDx 6plex Platform
9002038 Rotor-Gene Q MDx 5plex HRM, Priority Rotor-Gene Q MDx 5plex HRM, Priority includes the Rotor-Gene Q system, installation and extended warranty. Installation covers hardware and software installation of system and provides user with on site introductory training. Priority package extends warranty period of the system to 2 years with shipment to Repair Center Service has response turnaround time (repair) 7-10 days. One preventive maintenance visit is included for each year of the warranty; 2 preventive maintenance visits in total. Replacement system (Loaner) provision included (provision time 2-3 days) with transportation cost coverage. The service package includes all parts, labor and travel costs with installation performance and service visits documented on a GMP/GLP-compliant Field Service documents.
59110 EpiTect 96-well Bisulfite Kit (2) 2x EpiTect Bisulfite 96-well Plates, Reaction Mix, DNA Protect Buffer, Carrier RNA, Buffers
133225 NeXtalStock Sodium ac. pH 4.8 (200)
301305 SuperFect Transfection Reagent (1.2 ml) For 40 transfections in 60 mm dishes or 160 transfections in 12-well plates
970802 PyroMark Gold Q24 Reagents (5 x 24) For performing pyrosequncing reaction on the Q24
970470 BRAF Pyro Kit (24)
970061 MGMT Pyro Kit (48)
133209 NeXtalStock MES pH 5.0 (100)
292065 mericon Sheep Kit (96)
292045 mericon Turkey (96)
929501 QX Pro Calibration Marker (0.6 ml)
9012658 Cable, X-BCR board to buffer track reade
9012644 BGR Nadelrohr P7 Standardnadeln
9012595 Disposable Tips, 1100µl (960) Conducting disposable tips
206143 QIAGEN Multiplex PCR Kit (100) "For 100 x 50ul multiplex PCR reactions:
2x QIAGEN Multiplex PCR Master Mix (HotStarTaq® DNA Polymerase,Multiplex PCR Buffer, dNTP Mix) (providing a final concentration of 3 mM MgCl2, 3 x 0.85 ml),
5x Q-Solution (1 x 2.0 ml),
distilled water (2 x 1.7 ml)"
132107 EasyXtal 15-well DG-Tool (100)
337849 qBiomarker SYBR ROX FAST Mastermix 25 ml
762635 QIAsymphony PAXgene Blood RNA Kit (96)
204001 Rotor-Gene Sybr Green PCR Demo Kit (80)
203446 HotStarTaq Master Mix Kit (2500) "1x25 ml HotStarTaq Master Mix (providing a final concentration of 1.5mM MgCl2, and 200 uM each dNTP), containing 2500 units HotStarTaq DNA Polymerase total, and 2 x 20 ml RNase-free Water
-
Please note 2005 Product guide is incorrect - this product is NOT 30vials of 0.85ml"
203207 HotStarTaq DNA Polymerase (5000) "1 x 5000 units of HotStarTaq DNA Polymerase
10X PCR Buffer (contains 15 mM MgCl2)
5X Q-Solution
25 mM MgCl2"
203205 HotStarTaq DNA Polymerase (1000) "4 x 250 units HotStarTaq DNA Polymerase, 10x PCR Buffer,* 5x Q-Solution, 25 mM MgCl2
FOR MORE INFO ABOUT THIS PRODUCT PLEASE SEE HOTSTARTAQ DNA POLYMERASE 250 UNITS (203203)"
202602 HotStar HiFidelity Polymerase Kit (100) 100 units HotStar HiFidelity DNA Polymerase, 5x PCR Buffer containing dNTPs, 5x Q-Solution, 25 mM MgSO4, RNase free water
159932 Generation Capture Plate Kit (12)
159330 Harris UNI-CORE 1.25 mm Punch Kit (4)