Spectrum Analyzer

锚点2792

Features & Benefits


  • 100-Hz to 325-GHz Frequency Coverage
  • Continuous-Resolution Frequency Tuning
  • Up to 90-dB Viewable Dynamic Range
  • Built-In Frequency Counters Provide Frequency Determination to Within 0.0000001% (1 × 1e+9/day ref.)
  • Sensitivities to -110 dBm
  • Built-In Inligence for Signal Processing/Marker Functions
  • Push-Button Noise-Normalization Functions
  • Macro Capability with Nonvolatile Memory
  • Optional Switch-Selectable 50/75 ohm Impedances
  • Nonvolatile Memory for up to Nine Waveforms and Ten Front-Panel Settings
  • GPIB Programmability with Tektronix Codes and Formats


  • Applications
  • Manufacturing ATE
  • Avionics
  • Broadcasting
  • CATV
  • Cellular Radio
  • Design and Engineering
  • Nuclear Physics
  • Radio Astronomy
  • Salite Communications
  • Terrestrial Microwave
  • Two-Way Radio


Spectrum Analyzer

2792

Features & Benefits

  • 100-Hz to 325-GHz Frequency Coverage
  • Continuous-Resolution Frequency Tuning
  • Up to 90-dB Viewable Dynamic Range
  • Built-In Frequency Counters Provide Frequency Determination to Within 0.0000001% (1 × 1e+9/day ref.)
  • Sensitivities to -110 dBm
  • Built-In Inligence for Signal Processing/Marker Functions
  • Push-Button Noise-Normalization Functions
  • Macro Capability with Nonvolatile Memory
  • Optional Switch-Selectable 50/75 ohm Impedances
  • Nonvolatile Memory for up to Nine Waveforms and Ten Front-Panel Settings
  • GPIB Programmability with Tektronix Codes and Formats

Applications

  • Manufacturing ATE
  • Avionics
  • Broadcasting
  • CATV
  • Cellular Radio
  • Design and Engineering
  • Nuclear Physics
  • Radio Astronomy
  • Salite Communications
  • Terrestrial Microwave
  • Two-Way Radio

Characteristics

Frequency-Related

Frequency Range with Internal Mixers -10 kHz to 21 GHz

Frequency Range with External Mixers -325 GHz (Opt. 04)

Frequency Readout Accuracy (center or marker) -±[2% span + (CF × Ref.) + (2N + 25) Hz]: ±30 kHz at 1 GHz with 1 MHz span

Frequency Counter Accuracy -±[(CF × Ref.) + (5 + N) Hz + 1 LSD]: 10.013 kHz at 1 GHz, ±9 Hz at 1 GHz (Opt. 03)

Delta Count Accuracy -±[(D-F × Ref.) + (10 + 2N) + 1 LSD]: ±65 Hz for 1 MHz delta F

Frequency Reference Accuracy -≤2 × 1e+9/day (aging) Opt. 03

Frequency Stability (residual FM) -≤12 Hz at 1 GHz

Frequency Stability (drift) -<50 Hz/minute

Single-Sideband Phase Noise -(30 kHz offset and N=1)-103 dBc/Hz at 1 GHz

Frequency Span Range (plus 0 Hz and MAX) -2 kHz to 12 GHz

Frequency Span Accuracy -±5%

Delta Frequency Accuracy Marker Mode -1% of span

Resolution Bandwidth (6 dB) Range -1 kHz to 3 MHz

Resolution Bandwidth Selectivity -(-60 dB/-6 dB): ≤7.5:1

Video Bandwidth Range -3 Hz to 30 kHz

Amplitude-Related

Reference Level Range --117 to +30 dBm

Maximum Safe Input Power, CW -1 W (+30 dBm)

Maximum Safe Input Power, Pulse -75 W Pk (1 µs pulse, 0.1% duty factor)

CRT Display Range, Log -1 to 15 dB/div

CRT Display Range, Linear -39.6 nV/div to 2.8 V/div

Input Attenuator Range -0 to 60 dB in 10 dB steps

Dynamic Range (maximums) -

Compression to noise: 110 dB

Signal-to-distortion harmonic: 65 dB to 1.7 GHz; ≥100 dB 1.7 to 21 GHz

Signal-to-distortion intermodulation: 76 dB to 1.7 GHz; ≥100 dB 1.7 to 21 GHz

Viewable on CRT screen: 80 dB


Residual Response (no signal and zero RF attenuation) --95 dBm, (input terminated)

Second Harmonic Distortion, RF Frequency Range --60 dBc, (mixer level -40 dBm)

Second Harmonic Distortion --100 dBc

Microwave Frequency Range -(mixer level -20 dBm)

Third-Order Intermodulation Distortion --70 dBc; (mixer level -27 dBm)

Calibrator Accuracy -±0.3 dB

Gain Compression (1 dB) -0 dBm

Frequency Response (10 dB RF attenuation referred to cal signal) -

Band 1 (10 kHz to 1.8 GHz): ±3.0 dB

Band 2 (1.7 GHz to 5.5 GHz): ±4.0 dB

Band 3 (3.0 GHz to 7.1 GHz): ±4.0 dB

Band 4 (5.4 GHz to 18 GHz): ±5.0 dB

Band 5 (15 GHz to 21 GHz): ±7.0 dB


In-Band Flatness (with 10 dB RF attenuation) -

Band 1 (10 kHz to 1.8 MHz): ±2.0 dB

Band 2 (1.7 GHz to 5.5 GHz): ±3.0 dB

Band 4 (5.4 GHz to 18 GHz): ±4.0 dB

Band 5 (15 GHz to 21 GHz): ±5.5 dB


Displayed Average Noise Level (input terminated, narrowest resolution bandwidth, and video filter) -

Band 1 (1 kHz to 10 kHz): -60 dBm (typical)

Band 1 (10 kHz to 100 kHz): -70 dBm

Band 1 (100 kHz to 1 MHz): -90 dBm

Band 1 (1 MHz to 1.8 GHz): -110 dBm

Band 2 (1.7 GHz to 5.5 GHz): -108 dBm

Band 3 (3.0 GHz to 7.1 GHz): -108 dBm

Band 4 (5.4 to 12 GHz/12 to 18 GHz): -94/-89 dBm

Band 5 (15 GHz to 21 GHz): -88 dBm


IF Gain Uncertainty -±2 dB max over 107 dB range

Scale Fidelity, Log (80 dB range/90 dB range) -±2 dB max

Scale Fidelity, Linear -±5% of full scale

Input Attenuator Switching Accuracy (20 dB to 60 dB settings) -

0 to 1.8 GHz: ±0.5 dB/10 dB; ±1.0 dB max

1.8 to 18 GHz: ±1.5 dB/10 dB; ±3.0 dB max

18 to 21 GHz: ±3.0 dB/10 dB; ±6.0 dB max


Resolution Bandwidth Switching Uncertainty (reference BW = 3 MHz) -±0.4 dB

Time-Related

Sweep Time Range -200 µs/div to 100 sec/div

Sweep Time Accuracy -±5%

Marker Time Measurement Accuracy -±10%

Delta Marker Time Measurement Accuracy -±5%

Sweep Trigger -Free Run, Line, Video, Single, Ext.

External Input

RF Input Impedance -50 ohm nominal

VSWR (10 dB input attenuation) -

<2.5 GHz: 1.3:1 max

2.5 GHz to 6.0 GHz: 1.7:1 max

6.0 GHz to 18 GHz: 2.3:1 max

18 GHz to 21 GHz: 3.5:1 max


Local Oscillator Emission Level (0 dB input attenuation) -≥-70 dBm

Horizontal Input/Trigger Input -0 to +10 V/1 to 50 V

Video Input/Marker Input -0 to +4 V/0 to -10 V

External Output

Calibrator -100 MHz ±1 kHz, -20 dBm ±0.3 dB

1st Local Oscillator -2 to 6 GHz, +7.5 to +20 dBm

2nd Local Oscillator --12 to +5 dBm

Video Output (CRT center reference) -0.5 V of signal per div of video

Sweep Output (CRT center reference) -0.5 V/div; ±2.5 V max

Pen Lift -+5 V nominal; TTL-compatible

2nd IF Output (Opt. 42) -10 MHz, 0 dBm; 3 dB BW is 4.5 MHz

3rd IF Output -10 MHz, -5 dBm

Probe Power -+5 V, -15 V, +15 V; 100 mA max each

General Specifications

Power Requirements -

Voltage: 90-132/180-250 V AC

Frequency: 47-63 Hz

Power: 210 W max at 115 V AC, 60 Hz


Dimensions -

Without handle, feet, or cover: 175 × 327 × 499 mm (6.9 × 12.87 × 19.65 in.)

Weight (carrying), Nominal: 21.3 kg (46 lbs.)


Digital Storage -1000 pts horizontal, 250 pts vertical

Digitizing Rate -9 µs

Macro Programming -8 K

Nonvolatile Memory -9 waveforms, 10 control settings

Environmental (Per MIL-T-28800C, Type III, Class 3, Style C)

Electromagnetic Compatibility (consult data sheet for compliance details) -MIL-STD-461

Calibration Interval -1 Year

IEEE 488 (GPIB)

Interface Functions -SH1, AH1, T5, L3, SR1, RL1, PP1, SR1, RL1, PP1, DC1, DT1, and C0

Direct Plotter Output -Supports Tektronix HC100, HP7470A

Waveform Transfer Speed -165 ms/1000 pts

Safety -Listed FM 3810; Certified CSA