G型污泥螺杆泵的型号与性能参数表
型号 | 转速r/min | 流量 m3/h | 压力MPa | 电机KW | 扬程 m | 进口 mm | 出口 mm | 允许颗粒 直径mm | 允许纤维 长度mm |
G20-1 | 960 | 0.8 | 0.6 | 0.75 | 60 | Dy25 | Dy25 | 1.5 | 25 |
G25-1 | 960 | 2 | 0.6 | 1.5 | 60 | Dy32 | Dy25 | 2 | 30 |
G25-2 | 960 | 2 | 1.2 | 2.2 | 120 | Dy32 | Dy25 | 2 | 30 |
G30-1 | 960 | 5 | 0.6 | 2.2 | 60 | Dy50 | Dy40 | 2.5 | 35 |
G30-2 | 960 | 5 | 1.2 | 3 | 120 | Dy50 | Dy40 | 2.5 | 35 |
G35-1 | 960 | 8 | 0.6 | 3 | 60 | Dy65 | Dy50 | 3 | 40 |
G35-2 | 960 | 8 | 1.2 | 4 | 120 | Dy65 | Dy50 | 3 | 40 |
G40-1 | 960 | 12 | 0.6 | 4 | 60 | Dg80 | Dg65 | 3.8 | 45 |
G40-2 | 960 | 12 | 1.2 | 5.5 | 120 | Dg 80 | Dg65 | 3.8 | 45 |
G50-1 | 960 | 20 | 0.6 | 5.5 | 60 | Dg 100 | Dy80 | 5 | 50 |
G50-2 | 960 | 20 | 1.2 | 7.5 | 120 | Dy100 | Dy80 | 5 | 50 |
G60-1 | 960 | 30 | 0.6 | 11 | 60 | Dy125 | Dy100 | 6 | 60 |
G60-2 | 960 | 30 | 1.2 | 15 | 120 | Dy125 | Dy100 | 6 | 60 |
G70-1 | 720 | 45 | 0.6 | 11 | 60 | Dy150 | Dy125 | 8 | 70 |
G70-2 | 720 | 45 | 1.2 | 18.5 | 120 | Dy150 | Dy125 | 8 | 70 |
G 85-1 | 720 | 65 | 0.6 | 15 | 60 | Dy150 | Dy150 | 10 | 80 |
G 105-1 | 500 | 100 | 0.6 | 22 | 60 | Dy200 | Dy200 | 15 | 110 |
G 135-1 | 400 | 150 | 0.6 | 37 | 60 | Dy250 | Dy250 | 20 | 150 |
G型污泥螺杆泵的使用注意事项
1、开机前必先确定运转方向,不得反转。
2、严禁在无介质情况下空运转,以免损坏定子。
3、新安装或停机数天后的泵,不能立即起动,应先向泵体内注入适量机油,再用管子钳板动几转后才可起动。
4、输送高粘度或含颗粒及腐蚀性的介质后,应用水或深剂进行冲洗,防止阻塞,以免下次起动困难。
5、冬季应排除积液,防止冻裂。
6、使用过程中轴承箱内应定期加润滑油,发现轴端有渗流时,要及时处理或调换油封。
7、在运行中如发生异常情况,应立即停车检查原因,排除故障。
G型的故障原因及排除方法
故障 | 原因 | 排除方法 |
1、泵不能起动 | a、新泵转、定子配合过紧 | a、用工具人力帮助转动几圈 |
2、泵不出液 | a、旋转方向不对 | a、调整方向 |
3、流量达不到 | a、管路泄漏 | a、检查修理管路 |
4、压力达不到 | a、转子、定子磨损 | a、更换转、定子 |
5、电机过热 | a、电机故障 | a、检查电机、电压、电流、电频 |
6、流量压力急剧下降 | a、管道突然堵塞或泄漏 | 参照以下几项,逐项排除 |
7、轴密封处大量泄漏液体 | a、软填料磨损 | a、压紧或更换填料 |