中航时代 品牌
生产厂家厂商性质
北京市所在地
一、用途:
First, use:
ZJC-100KV固体绝缘材料电压击穿强度试验仪由电脑控制,数据采集方式通过光电隔离,有效解决试验过程中的抗干扰问题,软件操作使用方便,固体绝缘材料电压击穿强度试验仪能够实时显示动态曲线,同时升压速率无级可调,可以根据自己的需要进行升压速率调节,调节范围在0.1KV-3KV/S,使升压速率真正做到匀速、准确,并能够准确测出漏电电流的数据。可实时绘制试验曲线,显示试验数据,判断准确,并可保存,分析,打印试验数据。并且能够自动判别试样击穿并采集击穿电压数据及泄露电流,同时能够在击穿的瞬间电压迅速降低自动归零。软件系统操作方便,性能稳定,安全可靠。
ZJC-100KV by computer control, data acquisition by means of photoelectric isolation, effectively solve the interference problem in the test process, the software has the advantages of convenient operation, can display the dynamic curve, while the pressure rate can be adjusted, can according to their own needs to boost the rate of adjustment, adjustment in the range of 0.1KV-3KV/S, so that the pressure rate truly uniform and accurate, and can accuray measure the leakage current data. The test curve can be drawn in real time, the test data can be displayed, the judgment is accurate, and the test data can be saved, analyzed and printed. And it can automatically judge the breakdown of the sample and collect the breakdown voltage data and leakage current, and at the same time, the voltage can be reduced rapidly and automatically return to zero. The software system is easy to operate, stable in performance, safe and reliable.
二、符合标准:
Two, meet the standard:
1、GB1408.1-2006《绝缘材料电气强度试验方法》
1. GB1408.1-2006 "test method for electrical strength of insulating materials"
2、GB1408.2-2006《绝缘材料电气强度试验方法
2, "GB1408.2-2006 electrical strength of insulating materials test methods
第2部分:对应用直流电压试验的附加要求》
Part second: Additional requirements for tests using direct voltage "
3、GB/T1695-2005《硫化橡胶工频击穿电压强度和耐电压的测定方法》
3, GB/T1695-2005 "vulcanized rubber power frequency breakdown voltage strength and voltage measurement method"
4、ASTM D149《固体电绝缘材料工业电源频率下的介电击穿电压和介电强度的试验方法》
4. ASTM, D149, test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials at power frequency
三、主要技术要求:
Three, the main technical requirements:
1、设备输入电压: 交流 100KV (普通试验室电源均可兼容)
1, equipment input voltage: AC 100KV (common laboratory power supply can be compatible)
2、试验电压方式: 交流 0--100 KV ;
2, test voltage: AC 0--100 KV;
直流 0--100 KV;
DC 0--100 KV;
3、电器容量: 10KVA;
3, electric capacity: 10KVA;
4、试验方法: 0-100KV全量程可调;
4, test methods: 0-100KV full range adjustable;
5、击穿及耐压试验升压速率:
5, breakdown and withstand voltage test boost rate:
0.1 KV/S
0.1 KV/S
0.2 KV/S
0.2 KV/S
0.5 KV/S
0.5 KV/S
1.5 KV/S
1.5 KV/S
2 KV/S
2 KV/S
2.5 KV/S
2.5 KV/S
3.0 KV/S
3 KV/S
6、试验方式:
6, test method:
直流试验:1、匀速升压 2、阶梯升压 3、耐压试验
DC test: 1, 2, speed boost step-up voltage 3, pressure test
交流试验:1、匀速升压 2、阶梯升压 3、耐压试验
AC test: 1, 2, speed boost step-up voltage 3, pressure test
注:根据不同行业的标准,我们可以根据用户的要求,依据贵行业标准,为您定制行业标准所需的特殊测试功能。
Note: according to the standards of different industries, we can according to the requirements of the user, according to the standard of your industry, for you to customize the industry standard required special test function.
7、过电流保护装置应有足够灵敏度以保证试样击穿时在0.1S内切断电源。
7, over current protection device should have enough sensitivity to ensure that the sample breakdown in 0.1S cut off the power supply.
8、漏电电流选择: 1—100 mA可由计算机软件自由进行设定。
8, the leakage current selection: 1 - 100 mA can be set free by computer software.
9、本仪器采用*的无触点原件匀速调压方式,淘汰同类产品中机械传动升压方式。
9, the instrument adopts advanced non-contact original uniform pressure adjustment mode, eliminate similar products in the mechanical transmission way.
10、支持短时间内短路试验要求。(其它同类产品无此功能)
10, support for short time short circuit test requirements. (other similar products do not have this function)
11、一次试验可以同时做5个试样。(同类产品一次试验只能做一个试样)
11, a test can do 5 samples at the same time. A test can be made only once for a similar product
12、电压测量误差: ≤ 2%
12, voltage measurement error: = 2%
13、试验电压连续可调:0-100 KV
13, test voltage continuously adjustable: 0-100 KV
14、耐压时间设定: 0-6小时(可通过软件连续设定)
14, pressure time: 0-6 hours (set by software continuously set)
15、九级安全防护措施:
15, nine security measures:
(1) 超压保护
(1) overpressure protection
(2)试验过流保护
(2) test overcurrent protection
(3)试验短路保护
(3) test short circuit protection
(4)安全门开启保护
(4) safety door opening protection
(5)软件误操作保护
(5) software protection misoperation
(6)零电压复位保护
(6) zero voltage reset protection
(7)试验结束放电保护
(7) test over discharge protection
(8)独立保护接地
(8) independent grounding protection
(9)试验完成后电磁放电
(9) after the completion of test electromagnetic discharge
四、试验方式:
Four, test method:
1、绝缘试样空气中击穿或耐压试验
1, insulation breakdown or pressure test samples in air
2、绝缘试样浸油中击穿或耐压试验
2, insulation breakdown or compressive specimen immersed in test
3、绝缘试样空气中阶梯击穿或耐压试验
3, insulation breakdown voltage ladder or samples in air test
4、绝缘试样浸油中阶梯击穿或耐压试验
4, insulation breakdown voltage ladder or specimen immersed in test
五、试验软件:
Five, test software:
1、在试验过程中可对升压击穿过程绘制实时曲线,每次试验的升压曲线都由不同颜色构成,试验结束后可叠加对比材料的试验数据重复性。
, 1 in the test process can boost the breakdown process in real time curve drawing, each test boost curve are composed of different colors, after testing can be superimposed contrast material testing data repeatability.
2、可以随时调取当前及历史试验数据进行查看,编辑及修改参数。
2, can at any time to obtain the current and historical test data to view, edit and modify the parameters.
3、试验过程中可以随时修改试验条件及存储路径及自动存储试验结果。
3, the testing process can modify the test conditions and storage path and automatic storage test results at any time.
4、试验过程中,可随时通过软件决定本次试验是否有效,方便筛选试验结果。
4, during the test, may at any time through the software determines the test is effective, convenient screening test results.
5、可设置操作口令,做到专机专人操作,避免无关人员误操作。
5, set password, do special person operation, to avoid irrelevant personnel misoperation.
六、安全保护功能:
Six, safety protection function:
1、试验在试验箱中进行,试验箱门打开时电源加不到高压变压器输入端,即高压侧无电压。100KV测试设备高压电极距离试验箱壁的zui近距离大于270mm,50KV测试设备高压电极距离试验箱壁的zui近距离大于250mm,试验时即使人接触箱壁也不会有危险。
, 1 experiments were carried out in test box, test box when the door is opened to power and high voltage transformer input end, no voltage or high side. 100KV test equipment of high voltage electrode distance test box wall distance is greater than 270mm, 50KV test equipment of high voltage electrode distance test box wall distance is greater than 250mm, even when the test contact wall of the box will not be in danger.
2、设备要安装单独的保护地线。接保护地线,主要是减少试样击穿时对周围产生的较强的电磁干扰。也可避免控制计算机失控。
2, equipment to install a separate protective ground. The protective earth wire is mainly used to reduce the electromagnetic interference caused by the breakdown of the sample. Can also avoid the control computer out of control.
3、该试验设备的电路设有多项保护措施,主要有:过流保护、过压保护、漏电保护、短路保护、直流试验放电报警,电磁放电等。
3, the circuit test equipment is provided with a number of protective measures are: over-current protection, over-voltage protection, leakage protection, short-circuit protection, DC discharge alarm, electromagnetic discharge etc..
4、直流试验放电报警功能:在设备做完直流试验时,当开启试验门时设备会自动报警,直至使用设备上的放电装置放电后报
4, DC discharge test alarm function: in the equipment finished DC test, when open the door will automatically alarm test device, discharge device used on the device until the discharge after the newspaper