± 100ppm (typ.), ± 100ppm/8h (typ.) (CV, DC to 1kHz)
Output mode
CV, CC, DC and AC
Load regulation (DC mode)
CV mode : Within ± 0.1% (DC to 1kHz), ± 2% max. (1kHz to 20kHz) CC mode : Within ± 2% (DC to 1kHz), ± 20% max. (1kHz to 20kHz)
Line regulation (DC mode)
CV mode : Within ± 0.1% (DC to 1kHz), ± 1% max. (1kHz to 20kHz)
Frequency response
+0.2, -0.5dB : DC to 5kHz (45Hz to 5kHz for AC mode), +0, -3dB : 5kHz to 20kHz
Harmonic distortion (DC mode)
CV mode : 0.05% or less (10Hz to 1kHz), 1% or less (10kHz), 2.5% or less (20kHz) CC mode : 0.5% or less (10Hz to 1kHz), 2.5% or less (20kHz)
Output offset voltage/current
Adjustable to zero
Remote sensing
Possible in the CV and DC mode (DC to 1kHz)
Output type
Balanced , single-ended possibly, isolated between input and output
Power requirements
1φ 100V ± 10% (120, 200, 220 or 240V is available as option.) 48Hz to 62Hz
1φ 200V ± 10% (220 or 240V is available as option.) 48Hz to 62Hz
Dimensions(mm)
430(W) X 176(H) X 598(D)
430(W) X 265(H) X 598(D)
430(W) X 353.5(H) X 600(D)
430(W) X 442.5(H) X 600(D)
Weight
approx. 27kg
approx. 40kg
approx. 70kg
approx. 93kg
Remarks
*1 with respect to a capacitor-input rectifier circuit having a crest factor (I peak/I rms) of 2, in the CV mode *2 rms value for a sinewave current (at the rated output voltage, with Vcc= in AUTO mode)