品牌
生产厂家厂商性质
所在地
USB/HART调制解调器_智能物位变送器_恩德斯豪斯
面议JT33 TDLAS气体分析仪
面议Raman electro-optical (EO) fiber optic cables
面议RNF22电源和错误信接口息模块
面议RNB22系统电源
面议Micropilot FMR67B — 80 GHz雷达料位计
面议Micropilot FMR66B — 80 GHz雷达料位计
面议Micropilot FMR63B — 80 GHz雷达液位计
面议Micropilot FMR62B — 80 GHz雷达液位计
面议Micropilot FMR60B — 80 GHz雷达液位计
面议Fieldgate SFG500_智能型以太网_恩德斯豪斯
面议TTR31温度开关_恩德斯豪斯
面议Mass flow (liquid): ±0.5 % (standard), ±0.15 % (option)
Mass flow (gas): ±1 %
0 to 180 000 kg/h (0 to 6615 lb/min)
–40 to +150 °C (–40 to +302 °F)
PN 40, Class 300, 40K
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Mass flow (liquid): ±0.5 % (standard), ±0.15 % (option)
Mass flow (gas): ±1 %
0 to 180 000 kg/h (0 to 6615 lb/min)
–40 to +150 °C (–40 to +302 °F)
PN 40, Class 300, 40K
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
科里奥利质量流量
Flowmeter with minimized total cost of ownership with easy-to-use operation concept.
Measurement of liquids and gases in utility processes and basic applications.
Cost-effective general-purpose device – alternative to mechanical flowmeters. Fewer process measuring points – m*riable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).
Optimum usability – operation with devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.
DN 8 to 80 (⅜ to 3")
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Mass flow, temperature, Density (option), volume flow, corrected volume flow
Mass flow (liquid): ±0.5 % (standard), ±0.15 % (option)
Mass flow (gas): ±1 %
0 to 180 000 kg/h (0 to 6615 lb/min)
PN 40, Class 300, 40K
–40 to +150 °C (–40 to +302 °F)
Standard: –20 to +60 °C (–4 to +140 °F)
Stainless steel 1.4301 (304)
AlSi10Mg, coated
Standard: IP66/67, Type 4X enclosure
2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
HART, MODBUS RS485
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
ATEX
IECEx
cCSAus
EAC
NEPSI
INMETRO
JPN
UK Ex
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
CRN, PED
3.1 material
EC 1935, FDA, GB4806, cGMP
科里奥利质量流量
Flowmeter with minimized total cost of ownership with easy-to-use operation concept.
Measurement of liquids and gases in utility processes and basic applications.
Cost-effective general-purpose device – alternative to mechanical flowmeters. Fewer process measuring points – m*riable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).
Optimum usability – operation with devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.
DN 8 to 80 (⅜ to 3")
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Mass flow, temperature, Density (option), volume flow, corrected volume flow
Mass flow (liquid): ±0.5 % (standard), ±0.15 % (option)
Mass flow (gas): ±1 %
0 to 180 000 kg/h (0 to 6615 lb/min)
PN 40, Class 300, 40K
–40 to +150 °C (–40 to +302 °F)
Standard: –20 to +60 °C (–4 to +140 °F)
Stainless steel 1.4301 (304)
AlSi10Mg, coated
Standard: IP66/67, Type 4X enclosure
2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
HART, MODBUS RS485
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
ATEX
IECEx
cCSAus
EAC
NEPSI
INMETRO
JPN
Uk Ex
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
CRN, PED
3.1 material
EC 1935, FDA, GB4806, cGMP