美国controller 860系列微差压变送器

model 860美国controller 860系列微差压变送器

参考价: 面议

具体成交价以合同协议为准
2022-08-02 11:16:18
2245
产品属性
关闭
上海华脉实业有限公司

上海华脉实业有限公司

免费会员
收藏

组合推荐相似产品

产品简介

包括非线性滞后和非重复性,在固定温度下 **一个18-24VDC/AC输入所需的驱动500Ω的负载;也需要相同的输入1-10VDC输出 *** 3制4-20mA.美国controller 860系列微差压变送器

详细介绍

美国controller 860系列微差压变送器 
 

860

Specifications

Accuracy*:<+/-1.0% FSO
Stability:+/-0.5% FSO/yr
Thermal Effects:+/-0.075%/°C
Overpressure:1-10”WC = 100”WC
11-20”WC = 10x rated pressure
21-30”WC = 5x rated pressure
Over 30”WC = 45 PSI
FSO Pressure Range:0/0.25”WC up to 0/15PSI 
(bi-directional ranges available)
Compensated Range:10° to 50°C
Media:Non-corrosive, non-ionic gases
Operating Humidity:90% RH non-condensing
Operating Temp:-25° to 70°C
Input Supply**:12-24 VDC/24VAC**
Supply Current:<10mA (Voltage Output)
<30mA (Current Output)
Load Resistance:2KΩ minimum on voltage out, 250Ωmaximum loop resistance on 4-20mA output
(500Ω max loop resistance available upon request**)
Output Signal:1-5VDC, 1-6VDC, 1-10VDC** or 4-20mA*** (call for custom outputs)
Circuit Protection:Output limited and reverse voltage protected
Electrical Connections:Pluggable Screw Terminal Block
Pressure Connections:Barbed fitting for 1/8” ID tubing
Enclosure:Impact resistant ABS plastic
Dimensions:Approx. 3.5” x 2.7” x 1.4” (8.7cm x 6.8cm x 3.5cm)

* Includes non-linearity hysteresis and non-repeatability at a fixed temperature
** An input of 18-24VDC/AC is required to drive a 500Ω load; the same input is also required for a 1-10VDC output
*** 3-wire 4-20mA

Package Drawing

CLICK TO ENLARGE

 

How to Order

A typical order number consists of the model number, pressure range, pressure unit, output and mounting connection.

ModelTypeOutput SignalFSO Pressure RangeCalibration Pressure
860D = Differential or Gage*0…..1 to 5 volts0…..0.25″WC to 5″WCCustomer designated exact FSO
1…..1 to 6 volts1…..>5″WC to 13″WC
2…..1 to 10 volts**2…..>0.5PSI to 1PSI
3…..4-20mA (250Ω load)3…..>1PSI to 5PSI
4…..4-20mA (500Ω load)**4…..>5PSI to 15PSI
5…..Custom Output

Example: 865D-01 Cal Pressure = 6” WC. “Pressure Range” is not a specific number. Please indicate exact calibration pressure. (This unit has an output of 1-5 VDC and will be calibrated to 6” WC.) If a custom output is needed, the exact output must be specified.

* With a gage application, one of the two ports is vented to atmosphere
** With a 1-10 VDC output as well as with a 4-20mA output that needs to drive a 500Ω load a 18-24
VDC/24VAC input is required.