上海瑞齐生物科技有限公司作者
Monkey B Virus Antibody ELISA Kit
Use instruction
This kit is only used for researching.
Package size: :96
Purpose:
The kit is sued to assay the content of Monkey B Virus Antibody in porcine serum, blood plasma, and other related Liquid samples.
Experimental principle:
The kit use ELISA to assay Monkey B Virus Antibody level in the sample,use Purified Monkey B Virus an antigen to coat microtitration wells, make solid-phase an antigen, add Monkey B Virus Antibody in coated microtitration, Combined With HRP which labeled goat anti- Monkey antibody, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution and color develops, TMB becomes blue color At HRP enzyme-catalyzed, And at the effect of acid the color finally become yellow, the depth of color and the Monkey B Virus Antibody of sample were positively correlated, measure the optical densit (OD) at 450 nm with microtiter plate reader, calculate Monkey B Virus Antibody concentration by standard curve.
Materials provided with the kit
1 | wash solution | 20ml×1bottle | 7 | Stopp Solution | 6ml×1 bottle |
2 | HRP-Conjugate reagent | 6ml×1 bottle | 8 | Negative control | 0.5ml×1 bottle |
3 | Microelisa stripplate | 12well×8strips | 9 | Positivecontrol | 0.5ml×1 bottle |
4 | Sample diluent | 6ml×1 bottle | 10 | Instruction | 1 |
5 | Chromogen Solution A | 6ml×1 bottle | 11 | Closure plate membrane | 2 |
6 | Chromogen Solution B | 6ml×1/ bottle | 12 | Sealed bags | 1 |
Specimen requirements
1. extract as soon as possible after Specimen collection, Extracted according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can not be tested immediay, specimen can be kept in -20 ℃ to preserve, but repeated freezing and thawing should be avoided.
2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP activity of the horseradish peroxidase.
Assay procedure
1.Number: to sample correspond microtitration well and Number Sequence, each plate should be set feminine comparison 2 wells, masculine comparison 2 wells, blank comparison 1 well(don’t add sample and HRP-Conjugate reagent to blank comparison well, other each step the operation are same).
2.add sample:separay add Positive control and Negative control 50μl to the Positive and Negative well . add Sample dilution 40μl to testing sample well, then add testing sample 10μl. add sample to the bottom of ELISA plates coated well , don’t touch the well wall as far as possible, and Gently mix.
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
4.Configurate liquid: 30-fold (or 20-fold)wash solutiondiluted 30-fold (or 20-fold) with distilled water until 600ml,and reserve.
5.washing:Uncover Closure plate membrane, discardLiquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme:Add HRP-Conjugate reagent 50μlto each well, except the blank well.
7.incubate:Operation with 3.
8.washing:Operation with 5.
9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
11. assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
Determine the result
Test validity: the average of Positive control well≥1.00;the average of Negative control well ≤0.10.
Calculate Critical(CUT OFF) : Critical= the average of Negative control well + 0.15.
Negative control: sample OD< Calculate Critical(CUT OFF) isMonkey B Virus Antibody Negative control.
Positive control: ample OD≥ Calculate Critical(CUT OFF) is Monkey B Virus Antibody Positive control.
Important notes
1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature then use, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when
dilute . Washing does not affect the result.
3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
4. Please make specification curve when you assay, had better make duplicate well, if in the sample the testing material content is excessively high (The sample OD is bigger than the standard well OD 1.5 times ),please use Sample dilution to dilute certain multiple (n times),then assay. Please multiply total Dilution Times when calculate(×n×5).
5. Closure plate membrane only limits the disposable use, in order to avoid the overlapping pollution
6. The substrate please evade the light preservation
7. The test result determination must take the enzyme sign meter reading as a standard
8. All samples, washing buffer and each kind of reject should according to infective material process.
9. This reagent which different batch number component do not mix .
10. If it’s different form English instruction, take English instruction as the standard.
Storage and validity:
1.Storage: 2-8℃.
2.validity: six months.
全年征稿/资讯合作
联系邮箱:hbzhan@vip.qq.com
- 版权与免责声明
- 1、凡本网注明"来源:环保在线"的所有作品,版权均属于环保在线,转载请必须注明环保在线,https://www.hbzhan.com。违反者本网将追究相关法律责任。
- 2、企业发布的公司新闻、技术文章、资料下载等内容,如涉及侵权、违规遭投诉的,一律由发布企业自行承担责任,本网有权删除内容并追溯责任。
- 3、本网转载并注明自其它来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。
- 4、如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。
产品推荐更多>>
-