PRGM7-TT-SS-AF1F2-6-5-CV

PRGM7-TT-SS-AF1F2-6-5-CV

参考价: 订货量:
100 1

具体成交价以合同协议为准
2019-11-07 17:57:25
1379
属性:
加工定制:否;
>
产品属性
加工定制
关闭
深圳市扎克贸易有限公司

深圳市扎克贸易有限公司

延保会员
收藏

组合推荐相似产品

产品简介

PRGM7-TT-SS-AF1F2-6-5-CV
PRGM7 and PRGM6
隔离阀组应用于发电机组制动系统编辑
原制动系统存在的问题分析
光照发电厂原制动系统采用4HV330C-15型四通阀实现制动器供气、排气,该阀组密封于手动切换手柄直接接触,手动操作容易使密封件磨损、刮伤而导致串气,电厂自2008年投产以来,4台机组共发生阀组串气、漏气达20多次,存在机组运行时高速刹车的安全风险,严重影

详细介绍

PRGM7-TT-SS-AF1F2-6-5-CV
PRGM7 and PRGM6
The Ultimate
Purge-Blowback Systems 

Modes of Operation
 

PURGE ON

Shown with the Function Selector Handle * turned to "PURGE ON" and both service valves turned to "NORMAL". This is the NORMAL run mode.
 

 

TEST

Shown with the Function Selector Handle * turned to "PURGE ON" and the left service valve turned to "TEST".
When either of the service valves are turned to "TEST", the discharge of that flow cartridge is blocked downstream of the pressure indicator (PI). This "PI" was indicating process pressure, but it will now increase to indicate the purge inlet pressure as flow continues through the flow cartridge. The rate of pressure rise is a direct indication of flow rate through the cartridge; thus, serving as a good, positive indicator of two things: 1) Is the cartridge plugged? and 2) Is the purge and process pressure differential large enough?
If a more accurate indication of the flow rate is desired, open the vent valve to bring the (PI) down to zero pressure. Then close the vent valve and time how long it takes the flow cartridge to bring the (PI) back up to purge line pressure. Since the purge header pressure is constant throughout the plant, this recharge time should be fairly constant.
This vent and recharge procedure can also be used to try and clear a restricted flow cartridge. If it does not clear, then dial "PURGE OFF", vent off the pressure, and replace the cartridge.
 

 

PURGE OFF & TEST

Shown with the Function Selector Handle * turned to "PURGE OFF" and both service valves turned to "TEST".
This is the mode used to remove or replace a flow cartridge or pressure gauge. Use the vent system to bleed off ALL pressure prior to removing a cartridge or gauge.
 

 

FAST PURGE

Shown with the Function Selector Handle * turned to "FAST PURGE" on the left side. Mirror image results are obtained by dialing to the right side.
This mode is used to blast the tap lines clean. It is necessary to go on manual control before doing a fast purge. The most common need for this mode is to remove a liquid trap from within a vapor purge system. It is also used to remove sediments that may have collected in the line during a purge system failure.
 


 
Specifications
Max Ratings:
Teflon®:
2500psi @ 100°F
1500psi @ 220°F
*Ryton:
2500psi @ 220°F
1500psi @ 520°F
* DO NOT USE BELOW 200°F
Material:
All wetted and exposed parts are 316SS
Codes: Barstock, A479 - 316, A276-316; Cast, ASTM-A743 CF3M, ASTM-A-351 CF3M, A 276-316.
Design Codes:
ANSI B31.1, B16.5, NACE MR-01-75 (special order)
Spare Parts
Part Description:Part Number:Part Description:Part Number:
Flow Cartridge # 2
Flow Cartridge # 4
Flow Cartridge # 6
Flow Cartridge # 8
Ryton Face Seal (PRGM7 Only)
TSOFLOW2MZ
TSOFLOW4MZ
TSOFLOW6MZ
TSOFLOW8MZ
H80AMA02PZ
Viton® O-ring Cart. Seat Seal
Teflon® O-ring Cart. Seat Seal
Viton® O-ring Cart. Seal
Teflon® O-ring Cart. Seal
D71AAA05PZ
D70AAA05PZ
D71AAA06PZ
D70AAA06PZ

Viton® is a registered trademark of DuPont Dow Elastomers.
Teflon® is a registered trademark of DuPont.

Code Model
PRGM6 Single Purge Assembly
PRGM7 Double Purge Assembly
|Code Seals
|TT Teflon® / TFE O-Rings
|TV Teflon® / Viton® O-Rings
|RV Ryton / Viton® O-Rings
||Code Material
||SS Stainless Steel, 316
|||Code Connections
|||OutletInlet Description
|||AF1F2 Flanged Outlet to Manifold x 1/4" FNPT Inlet
||| PRGM6 Only
|||F2F2 1/4" FNPT Outlet (No Manifold) x 1/4" FNPT Inlet
|||||Code Flow Capsule Size
|||||#2 3.2 SCFH Air @ 10 Psi
|||||#4 1.0 SCFH Air @ 10 Psi
|||||#6 .40 SCFH Air @ 10 Psi
|||||#8 .10 SCFH Air @ 10 Psi
||||||Code Gauges (optional) leave blank if not required
||||||3 0-16 KG/CM² Stainless Steel
||||||5 0-40 KG/CM² Stainless Steel
||||||7 0-200 Psi Stainless Steel
||||||8 0-1000 Psi Stainless Steel
|||||||Code Manifold (PRGM7 Only)
|||||||GP3FU GP3FU-T-SS 3-Valve Manifold
||||||||Code Options
||||||||CV Check Valve Stainless Steel
||||||||PRGM6 Only
||||||||MB Mounting Bracket Kit for 2" pipe
||||||||PRGM7 Only
||||||||F2 1/4" FNPT GP3FU Outlet (Flange Std.)
||||||||| 
 Model Number
品牌/型号/订货号中文品名英文品名中国纳税编码毛重净重
d-a-mfg / PRGM6-TT-SS-AF1F2-#6-CV气动传动阀Pneumatic transmission valve10901190100000000001.00000.0000
d-a-mfg / D70AAA05PZ---------------
d-a-mfg / PRGM6-TT-SS-F1F2-#6---------------
d-a-mfg / PRGM7-T-SS-AF1F2-#6---------0.00000.0000
d-a-mfg / PRGM7-TV-SS-F2F2-#2-5---------------
d-a-mfg / PRGM7-TV-SS-AF1F2-#2 -8---------0.00000.0000
d-a-mfg / PRGM7-TV-SS-AF1F2-#6-8---------------
d-a-mfg / prgm7-tv-ss-af1f2-#6---------------
d-a-mfg / PRGM7-TV-SS-F2F2-#2-5---------0.00000.0000
d-a-mfg / PRGM7-TT-SS-AF1F2-#2-GP3FU---------------
d-a-mfg / PRGM6-TT-SS-F2F2-#6---------0.00000.0000
d-a-mfg / PRGM7-TV-SS-AF1F2#6-5-GP3FU-CV---------0.000010.5000
d-a-mfg / PRGM7-TT-SS-AF1F2-#6-CV气动传动阀Pneumatic transmission valve10901190100000000001.00000.0000
d-a-mfg / PRGM7-TV-SS-AF1F2-#6---------0.00000.0000
d-a-mfg / PRGM7-TV-SS-AF1F2-#8-8-GP3FU-CV---------------
d-a-mfg / PRGM6-TT-SS-F2F2-#6-7-CV---------------
d-a-mfg / D70AAA06PZ---------------
d-a-mfg / PRGM7-TT-SS-AF1F2-#6-GP3FU---------------
d-a-mfg / 2 PRGM7-TT-SS-AF1F2-#6-GP3FU---------------
d-a-mfg / PRGM7-TV-SS-AF1F2-#2---------------
d-a-mfg / PRGM6-TT-SS-F2F2-#6-5-CV-MB

 