cGMP ELISA KIT

cGMP ELISA KIT

参考价: 面议

具体成交价以合同协议为准
2024-04-23 16:13:26
67
产品属性
关闭
武汉纽斯特生物科技有限公司

武汉纽斯特生物科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

MonoclonalAnti-cGMPAntibodyBasedDirectcGMPELISAKit(NewNon-acetylatedVersion)CatalogNo.802045x96WellKit产品描述环磷酸鸟苷(鸟苷-3´,5´-环化一磷酸,cGMP)在许多生理过程中发挥着重要的调控作用

详细介绍

Monoclonal Anti-cGMP EIA Kit without Acetylation [80103]
[1x96 well]


Product Highlight

  • Based on the unique mouse monoclonal Anti-cGMP antibody
    It is the only EIA kit on the market with monoclonal anti-cGMP antibody (all other kits are based on polyclonal anti-cGMP antibodies). 
     

  • No more hazardous chemical () for your cGMP assay 
    The monoclonal Anti-cGMP antibody has similar affinities for non-acetylated cGMP and acetylated cGMP. Thus acetylation with the acetic anhydride is permanently eliminated from the assay.
     

  • Super sensitivity and selectivity 
    The monoclonal Anti-cGMP antibody displays >108 fold of selectivity over cAMP, GTP, and other nucleoside analogues. 
    The Anti-cGMP EIA Kit provides significantly improved sensitivity and selectivity over other kits based on polyclonal anti-cGMP antibodies on the market.
     

  • Shortest assay time and high-throughput format 
    The Anti-cGMP EIA Kit is the best choice for drug screenings.

Product Description

    Guanosine 3',5'-cyclic monophosphate (cyclic GMP; cGMP) plays critical regulatory roles in many physiological processes. cGMP is produced from GTP by guanylyl cyclases and is degraded by phosphodiesterases. Stimulation of guanylyl cyclases or inhibition of phosphodiesterases can increase cellular cGMP concentrations. Inhibitors of the cGMP-specific phosphodiesterases are used for treating human diseases. For example, inhibitors of cGMP specific phosphodiesterase type 5 (such as Viagra and Cialis) are used for treating erectile dysfunction.

    To screen for inhibitors of phosphodiesterases or stimulators of guanylyl cyclases, it is essential to have a fast, sensitive, selective and reproducible method to measure the cGMP concentrations. This is especially true for the initial screenings given the possible weaker effects of larger pools of compounds.

    Currently available other ELISA kits measuring cGMP levels are based on the non-affinity-purified polyclonal anti-cGMP antibody. Despite the claimed selectivity, these polyclonal anti-cGMP antibodies display certain cross-reactivity with cAMP or GTP. In most cell types, cGMP is present at levels ~100 fold lower than cAMP.

    NewEast Biosciences cGMP ELISA kit is based on the unique mouse monoclonal anti-cGMP antibody. This monoclonal anti-cGMP antibody displays >108 fold of selectivity over cAMP, GTP, and other nucleoside analogues. NewEast Biosciences cGMP ELISA kit provides significantly improved sensitivity and selectivity over other kits based on polyclonal anti-cGMP antibodies. Our monoclonal anti-cGMP antibody-based ELISA kit also avoids the batch-to-batch variations associated with polyclonal antibody productions from animals, thus providing the reproducibility in the long run.

    Furthermore, while polyclonal anti-cGMP antibodies used in other ELISA kits have higher affinity for acetylated cGMP than non-acetylated cGMP, NewEast Biosciences monoclonal anti-cGMP antibody has similar affinities to non-acetylated and acetylated cGMP molecules. Therefore, acetylation treatments of samples and standards are not needed in NewEast Biosciences cGMP ELISA kit. This significantly reduces the time for the assay. The avoidance of organic reagents used in the acetylation process provides a safe and healthy work environment.

Principle Outline

    NewEast Biosciences cGMP ELISA Kit is a competitive immunoassay to measure the cGMP levels, either from cell extracts or from in vitro guanylyl cyclase assays. Briefly, multi-well plates are coated with goat-anti-mouse serum. cGMP in cell extracts or in in vitro guanylyl cyclase assays will competitively bind to the monoclonal anti-cGMP antibody in the presence of fixed amounts of cGMP-conjugated horse-radish peroxidase. Known amounts of cGMP are used as standards to generate the calculation curve. After a short incubation, the excess reagents are washed away and substrate is added. The multiwell plates are then read on a microplate reader at 450 nm. The intensity of the yellow color is inversely proportional to the concentration of cGMP in samples. The measured optical density is used to calculate the concentration of cGMP in samples based on the curve from the cGMP standards.

  •     

    
    
Publications:
1.  
    Pflugers Arch. 2013 Feb;465(2):333-41
2.  
    Circ Res. 2012 Jan 20;110(2):295-303
3.  
    Proc Natl Acad Sci U S A. 2012 Oct 23;109(43):17681-6
4.  
    Cardiovasc Res. 2011 Jun 1;90(3):565-72
5.  
    Gen Comp Endocrinol. 2011 Sep 15;173(3):467-74
6.  
    PLoS One. 2011;6(11):e27187
7.  
    Comp Biochem Physiol B Biochem Mol Biol. 2011 Jan;158(1):46-55
8.  
    Circ Res. 2010 Nov 12;107(10):1232-40
9.  
    PLoS One. 2013 Aug 28;8(8):e72155
10.  
    Biochemistry. 2009 May 26;48(20):4417-22
11.  
    Journal of Molecular and Cellular Cardiology Volume 60, July 2013, Pages 72–83
12.  
    genetics.113.152660v1 194/4/885
13.  
    Redox Biology Volume 1, Issue 1, 2013, Pages 498–507
14.  
    Journal of Cardiovascular Pharmacology: November 2014 - Volume 64 - Issue 5 - p 452-459
15.  
    Hepatology Volume 60, Issue 6, pages 1929–1941, December 2014



上一篇:ELISA试验结果空白背景高造成原因 下一篇:通蔚生物教您如何降低Elisa试剂盒误差率的方法 ​
热线电话 在线询价
提示

请选择您要拨打的电话: