产品规格参数LaserwavelengthWithimmersionoptic:532nm

详细介绍

产品规格参数

  • Laser wavelength

    With immersion optic:
    532 nm, 785 nm, 1000 nm
    With bIO-Optic:
    785 nm, 1000 nm
    With Raman optic system for single use:
    785 nm, 1000 nm

  • Body and window materials

    Rxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steel

    • 测量原理

      Raman spectroscopy

    • Laser wavelength

      With immersion optic:
      532 nm, 785 nm, 1000 nm
      With bIO-Optic:
      785 nm, 1000 nm
      With Raman optic system for single use:
      785 nm, 1000 nm

    • Spectral coverage

      Probe spectral coverage is limited by the coverage of the analyzer being used.

    • Temperature

      Temperature, Rxn-10 probe:
      -10 to 70 °C

    • Relative humidity

      20-60% non-condensing

    • Maximum laser power into probehead (mW)

      <499

    • Sample interface

      Based on the sampling optic selected

    • Body and window materials

      Rxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steel

    • Fiber optic cable

      Design: PVC jacketed, proprietary construction
      Connections: proprietary electro-optic (EO), or FC to EO fiber converter(s) for non-embedded systems
      Temperature: -40 to 70 °C
      Length: 5 to 25 m standard, available in 5 m increments
      Minimum bend radius: 152.4 mm

    • Length

      Rxn-10 probe (including fiber cable bend radius): 356 mm

    • Diameter (mm)

      Rxn-10 probe: 19

    • Working distance (mm)

      Based on the sampling optic selected

    • 测量原理

      Raman spectroscopy

    • Laser wavelength


      532 nm, 785 nm, 1000 nm

    • Spectral coverage

      Probe spectral coverage is limited by the coverage of the analyzer being used.

    • Temperature

      Temperature, Rxn-10 probe:
      -10 to 70 °C

    • Relative humidity

      20-60% non-condensing

    • Maximum laser power into probehead (mW)

      <499

    • Sample interface

      Based on the sampling optic selected

    • Body and window materials

      Rxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steel

    • Fiber optic cable

      Design: PVC jacketed, proprietary construction
      Connections: proprietary electro-optic (EO), or FC to EO fiber converter(s) for non-embedded systems
      Temperature: -40 to 70 °C
      Length: 5 to 25 m standard, available in 5 m increments
      Minimum bend radius: 152.4 mm

    • Length

      Rxn-10 probe (including fiber cable bend radius): 356 mm

    • Diameter (mm)

      Rxn-10 probe: 19

    • Working distance (mm)

      Based on the sampling optic selected