Capacity: 1~15 m3/minMax. working pressure : ≤1.5MPa (15barg)Max. inlet temperature : 80℃Max. ambient temperature : 50℃Min. ambient temperature : 5℃Max. cooling water temperature : 35℃Cooling type : a......

详细介绍

Designed to handle high inlet temperatures up to 80℃.
High efficiency all-in-one heat exchanger design enable our dryers light weight and small foot print.
Environment friendly HFC refrigerants R134a and R407C.
Less point of welding, lower leakage risk.
Large pre-cooler & counter flow design, save energy up to 25%.
Demister water separator, 99+% efficiency dew point guarantee, much better than cyclone separator.
Rugged hermetically refrigeration compressor provide years of trouble free service.
Automatic refrigeration temperature control system maintains precise chilled air temperature.
Refrigeration side insulation to save energy.
Various power supply for option.

Technical Specification

Model Air
Connection
Capacity
m³/min
Power Supply Absorbed
Power  (kW)
Dimension  mm Weight
m³/min CFM V/Ph/Hz L W H kg
RSLF-12-HT Rc1/2" 1.2 42 230/1/50 0.30 650 320 550 35
RSLF-24-HT Rc1" 2.4 85 230/1/50 0.61 800 420 600 70
RSLF-30-HT Rc1" 3 106 230/1/50 0.76 800 420 600 75
RSLF-60-HT Rc1-1/2" 6 212 230/1/50 1.09 750 695 1260 125
RSLF-80-HT Rc1-1/2" 8 282 230/1/50 1.45 750 695 1260 128
RSLF-100-HT Rc1-1/2" 10 353 230/1/50 1.82 750 695 1260 133
RSLF-120-HT Rc2" 12 424 230/1/50 2.18 1000 840 1450 165
RSLF-150-HT Rc2" 15 530 230/1/50 2.73 1000 840 1450 175


Rated Conditions
Working pressure : 0.7MPag / 100psig
Inlet temp : 60 ℃ / 140 ℉
Ambient temp : 38℃ / 100 ℉
Working Range
Max. working pressure : 1.5MPag / 218psig
Max. inlet temperature : 80 ℃ / 176 ℉
Max. ambient temperature : 50℃ / 122 ℉
Min. ambient temperature : 5℃ / 41 ℉
Avaliable Options
Higher working pressure
Different power supply
Timed drain or zero loss drain
Higher Capacity


Correction Factors

Actual Capacity (m³/min) = Nominal Capacity × KA × KB × KC

Working Pressure (KA) Mpag 0.4 0.5 0.6 0.7 0.8 0.9
psig 58 73 87 102 116 131
CFP 0.86 0.92 0.93 1.00 1.04 1.08
Mpag 1.0 1.1 1.2 1.3 1.4 1.5
psig 145 160 174 189 203 218
CFP 1.11 1.15 1.18 1.22 1.25 1.28


Inlet Temperature (KB) 50 55 60 65 70 75 80
122 131 140 149 158 167 176
CFT 1.03 1.02 1.00 0.87 0.78 0.70 0.64


Ambient Temperature (KC) 25 30 35 38 40 45 50
77 86 95 100 104 113 122
CFT 1.15 1.10 1.02 1.00 0.89 0.79 0.69