其他品牌 品牌
经销商厂商性质
上海所在地
西门子S120变频器维修
¥1500西门子S120驱动器维修
面议西门子伺服电机代理商
¥1680西门子S7-200SMART PLC代理商
¥588西门子CPU SR60控制器6ES7288-1SR60-0AA1 PLC
¥100西门子828D车削/铣削/车床铣床磨床数控系统 机床配件
¥1.2西门子6ES7518-4AX00-1AC0处理器CPU1518 PLC
¥15000西门子CPU1518处理器6ES7518-4AP00-0AB0 PLC
¥15000西门子数控控制单元6SL3040-0MA00-0AA1 伺服系统
¥1680西门子控制单元6SL3040-0MA00-0AA0数控 伺服系统
¥1680西门子调节型接口模块6SL3100-0BE21-6AB0 伺服电机
¥1500西门子调节型电源模块6SL3130-7TE28-0AA3 伺服电机
¥1680西门子G120变频器功率单元,模块式变频器,3AC 380-480V,USS/Modbus RTU 版本,PROFINET 版本,PROFIBUS DP 版本三个版本控制单元可供选择组合,满足客户的需求
SINAMICS G120C, frame sizes FSAA to FSF, with Intelligent Operator Panel IOP‑2
SINAMICS G120C compact converters offer a well-balanced combination of features to address a wide range of applications. They are compact, rugged devices that are easy to operate and can be optionally equipped with a basic or advanced operator panel.
SINAMICS G120C converters are especially suitable when it comes to meeting the requirements of system integrators, OEMs and distributors regarding high productivity and tailored performance.
G120C变频器概述
Introduction
SINAMICS G120C compact converters
Line-side components
DC link components
Load-side power components
Supplementary system components
Spare parts
西门子G120变频器功率单元
G120C紧凑型变频器
SINAMICS G120C紧凑型变频器,在许多方面为同类变频器的设计树立了*。包括它紧凑的尺寸,便捷的快速调试,简单的面板操作,方便友好的维护以及丰富的集成功能都将成为新的标准。
SINAMICS G120C是专门为满足OEM用户对于高和节省空间的要求而设计的变频器,同时它还具有操作简单和功能丰富的特点。这个系列的变频器与同类相比相同的功率具有更小的尺寸,并且它安装快速,调试简便,以及它友好的用户接线方式和简单的调试工具都使它与众不同。集成众多功能:安全功能(STO,可通过端子或PROFIsafe),多种可选的通用的现场总线接口,以及用于参数拷贝的存储卡槽。
SINAMICS G120C 变频器包含三个不同的尺寸功率范围从0.55kW到18.5kW。为了提高能效,变频器集成了矢量控制实现能量的优化利用并自动降低了磁通。该系列的变频器是全集成自动化的组成部分,并且可选PROFIBUS, Modbus RTU,CAN以及USS 等通讯接口。操作控制和调试可以快速简单地采用PC机通过USB接口,或者采用BOP-2(基本操作面板)或IOP(智能操作面板)来实现。[2]
5日常维护
操作人员必须熟悉西门子变频器的基本工作原理、功能特点, 具有电工操作常识。在对变频器日常维护之前,必须保证设备总电源全部切断;并且在变频器显示*消失的3-30分钟(根据变频器的功率)后再进行。应注意检查电网电压,改善变频器、电机及线路的周边环境,定期清除变频器内部灰尘,通过加强设备管理极大限度地降低变频器的故障率。
1、冷却风扇
变频器的功率模块是发热严重的器件,其连续工作所产生的热量必须要及时排出,一般风扇的寿命大约为20kh~40kh。按变频器连续运行折算为3~5年就要更换一次风扇,避免因散热不良引发故障。
2、滤波电容
中间电路滤波电容:又称电解电容,该电容的作用:滤除整流后的电压纹波,还在整流与逆变器之间起去耦作用,以消除相互干扰,还为电动机提供必要的无功功率,要承受极大的脉冲电流,所以使用寿命短,因其要在工作中储能,所以必须长期通电,它连续工作产生的热量加上变频器本身产生的热量都会加速其电解液的干涸,直接影响其容量的大小。正常情况下电容的使用寿命为5年。建议每年定期检查电容容量一次,一般其容量减少20%以上应更换。
3、防腐剂的使用
因一些公司的生产特性,各电气mcc室的腐蚀气体浓度过大,致使很多电气设备因腐蚀损坏(包括变频器)。
为了解决以上问题可安装一套空调系统,用正压新鲜风来改善环境条件。为减少腐蚀性气体对电路板上元器件的腐蚀,还可要求变频器生产厂家对线路板进行防腐加工,维修后也要喷涂防腐剂,有效地降低了变频器的故障率,提高了使用效率。
4、给变频器除尘:变频器根据使用环境的不同,应定期检查散热通道、及电路板中有无积累灰尘,一般每半年清理一次,至少也要一年清理一次,以确保变频器散热良好,使其避免因散热不良而引发故障。
在保养的同时要仔细检查变频器,定期送电,带电机工作在2hz 的低频约10分钟,以确保变频器工作正常。
G120C 一体式变频器
USS/Modbus RTU 版本
不带滤波器订货号
6SL3210-1KE11-8UB2 0.55kW
6SL3210-1KE12-3UB2 0.75kW
6SL3210-1KE13-2UB2 1.1kW
6SL3210-1KE14-3UB2 1.5kW
6SL3210-1KE15-8UB2 2.2kW
6SL3210-1KE17-5UB1 3kW
6SL3210-1KE18-8UB1 4kW
6SL3210-1KE21-3UB1 5.5kW
6SL3210-1KE21-7UB1 7.5kW
6SL3210-1KE22-6UB1 11kW
6SL3210-1KE23-2UB1 15kW
6SL3210-1KE23-8UB1 18.5kW
6SL3210-1KE24-4UB1 22kW
6SL3210-1KE26-0UB1 30kW
6SL3210-1KE27-0UB1 37kW
6SL3210-1KE28-4UB1 45kW
6SL3210-1KE31-1UB1 55kW
6SL3210-1KE31-4UB1 75kW
6SL3210-1KE31-7UB1 90kW
6SL3210-1KE32-1UB1 110kW
6SL3210-1KE32-4UB1 132kW
带滤波器订货号
6SL3210-1KE11-8AB2
6SL3210-1KE12-3AB2
6SL3210-1KE13-2AB2
6SL3210-1KE14-3AB2
6SL3210-1KE15-8AB2
6SL3210-1KE17-5AB1
6SL3210-1KE18-8AB1
6SL3210-1KE21-3AB1
6SL3210-1KE21-7AB1
6SL3210-1KE22-6AB1
6SL3210-1KE23-2AB1
6SL3210-1KE23-8AB1
6SL3210-1KE24-4AB1
6SL3210-1KE26-0AB1
6SL3210-1KE27-0AB1
6SL3210-1KE28-4AB1
6SL3210-1KE31-1AB1
6SL3210-1KE31-4AB1
6SL3210-1KE31-7AB1
6SL3210-1KE32-1AB1
6SL3210-1KE32-4AB1
PROFINET 版本
不带滤波器订货号
6SL3210-1KE11-8UF2
6SL3210-1KE12-3UF2
6SL3210-1KE13-2UF2
6SL3210-1KE14-3UF2
6SL3210-1KE15-8UF2
6SL3210-1KE17-5UF1
6SL3210-1KE18-8UF1
6SL3210-1KE21-3UF1
6SL3210-1KE21-7UF1
6SL3210-1KE22-6UF1
6SL3210-1KE23-2UF1
6SL3210-1KE23-8UF1
6SL3210-1KE24-4UF1
6SL3210-1KE26-0UF1
6SL3210-1KE27-0UF1
6SL3210-1KE28-4UF1
6SL3210-1KE31-1UF1
6SL3210-1KE31-4UF1
6SL3210-1KE31-7UF1
6SL3210-1KE32-1UF1
6SL3210-1KE32-4UF1
带滤波器订货号
6SL3210-1KE11-8AF2
6SL3210-1KE12-3AF2
6SL3210-1KE13-2AF2
6SL3210-1KE14-3AF2
6SL3210-1KE15-8AF2
6SL3210-1KE17-5AF1
6SL3210-1KE18-8AF1
6SL3210-1KE21-3AF1
6SL3210-1KE21-7AF1
6SL3210-1KE22-6AF1
6SL3210-1KE23-2AF1
6SL3210-1KE23-8AF1
6SL3210-1KE24-4AF1
6SL3210-1KE26-0AF1
6SL3210-1KE27-0AF1
6SL3210-1KE28-4AF1
6SL3210-1KE31-1AF1
6SL3210-1KE31-4AF1
6SL3210-1KE31-7AF1
6SL3210-1KE32-1AF1
6SL3210-1KE32-4AF1
PROFIBUS DP 版本
不带滤波器订货号
6SL3210-1KE11-8UP2
6SL3210-1KE12-3UP2
6SL3210-1KE13-2UP2
6SL3210-1KE14-3UP2
6SL3210-1KE15-8UP2
6SL3210-1KE17-5UP1
6SL3210-1KE18-8UP1
6SL3210-1KE21-3UP1
6SL3210-1KE21-7UP1
6SL3210-1KE22-6UP1
6SL3210-1KE23-2UP1
6SL3210-1KE23-8UP1
带滤波器订货号
6SL3210-1KE11-8AP2
6SL3210-1KE12-3AP2
6SL3210-1KE13-2AP2
6SL3210-1KE14-3AP2
6SL3210-1KE15-8AP2
6SL3210-1KE17-5AP1
6SL3210-1KE18-8AP1
6SL3210-1KE21-3AP1
6SL3210-1KE21-7AP1
6SL3210-1KE22-6AP1
6SL3210-1KE23-2AP1
6SL3210-1KE23-8AP1
G120C变频器参数设置步骤
一、参数设置步骤
1.使用网线连接上G120C变频器,打开博图找到相应的变频器转至在线模式。
在线模式
2.进入“参数设置”
选择参数
3.进入参数模式后将默认模式改成扩展参数。
模式选择
4.在下方框内直接输入参数编号可直接查到并对其进行修改。
编号输入
5.点击左侧菜单选择“保存/复位”选项,进入保存复位画面。在如下的画面红色框中点击“保存”按钮,讲设置的参数保存至变频器的EEPROM中,如果设置的参数没有保存至EEPROM中变频器在断电后设置的参数会丢失,完成保存设置后把变频器转至离线模式,变频器设定完毕。
保存
二、主要参数
1、加减速时间,最小减速时间,VDC直流母线控制模式,复合制动系数,VDC直流母线向应系数,控制模式,极限电流,直流制动激活。
主要参数
三、报警屏蔽设置
1.P2118是屏蔽的报警编号,P2119是无报警信息设置,两者是一一对应使用。