品牌
其他厂商性质
所在地
MinusK CT-1隔振台/减震台/防震台
面议MinusK BM-6隔振台/减震台/防震台
面议MinusK BM-10隔振台/减震台/防震台
面议MinusK BM-4隔振台/减震台/防震台
面议MinusK WS-4隔振台/减震台/防震台
面议MinusK BM-8隔振台/减震台/防震台
面议MinusK BM-1隔振台/减震台/防震台
面议SOTOMD隔振器/减震台/防震系统
面议SOTOTT隔振台/减震台/防震台
面议ARISTT主动隔振台/主动减震台/主动防震台
面议MinusK WS-4显微镜低频减震台/减振台
面议To One减震台_桌上型气浮隔振台
面议SotoTT减震台/隔振台
光学显微镜减震台,原子力显微镜隔振台,电子天平防震台;光学轮廓仪减震台,激光设备隔振台,半导体设备防震台,白光干涉仪减震台,超快激光系统隔振台,纳米压痕机减震台,汽车变速箱隔振台,微电机系统MEMS减震台......
The Most Advanced Vibration Absorption Systems
A lightweight and compact vibration absorption systems allows to significantly reduce unwanted vibrations translated to working environment from noise Pumps, Compressors, etc. Developed by engineers, physicists, and leading industry consultants with expertise in vibration isolation and precision instruments, SotoTT effectiveness at significantly absorb vibrations and disturbances.
SotoTT | Device Capabilities | Dimensions(mm) | Load Capacity(Kg) |
SotoTT75 | Passive Anti-vibration System | 300X450X62 | 15~75 |
SotoTT75X | Passive Anti-vibration System | 400X500X80 | 15~75 |
SotoTT100 | Passive Anti-vibration System | 400X500X80 | 40~100 |
SotoTT150 | Passive Anti-vibration System | 400X500X80 | 70~150 |
SotoTT180 | Passive Anti-vibration System | 500X600X80 | 80~180 |
SotoTT200 | Passive Anti-vibration System | 600X800X80 | 90~200 |
SotoTTXXX-M | Passive Anti-vibration System | Customized | Customized |
Comparison analizes SotoTTXXX versus Pneumatictables
Pneumatic Tables | SotoTTxxx | |
Low Frequency Resonance | 2-5Hz | None |
Vibration Absorption | Low vibration absorption,due low stiffness and low damping | Specially designed passive damping is effective for wide frequency bandwidth |
Stifness | Low stiffness in X,Y,Z axes | ~80 times stiffer then pneumatic systems |
Barometric Pressure Sensitive | Air Based Systems Susceptible to changes in barometric pressure variations caused by HVAC and HEPA systems, opening/closing doors in lab rooms, etc. In Air Based Systems Tiny pressure changes can impact payload vibrations even more than floor vibrations | Not effected by pressure changes |
Amplification at Resonance Frequency | 4-9 times | None |
Very sensitive to center of gravity in high position, easily get unstable (due to low stiffness and low damping) | Low sensitive to high center of gravity, due to high stiffness (~80 times stiffer) and high level of damping |
Step respond – respond to intentional or unintentional disturbance (sample placement, tool placement, etc.)
Industry fields and Applications
1. Analytical tools –table-top AFM
2. Biology & Life Science - Inverted Microscope and Micromanipulator, Optical Microscope
3. IVF laboratory – Inverted Microscope and Micromanipulator
4. Scientific laboratories – precision balances and scales, confocal microscopes
5. Vacuum pumps and compressors