丹富斯静态平衡阀产品概述 流量平衡阀,静态流量平衡阀作用
静态平衡阀,是液体管路流量调节阀,其作用是方便、准确的调节流量,有效地解决管网系统中存在的冷热不均、水力失调的问题。它不但有良好的调节性能,而且有开度显示和开度功能,广泛用于供暖和空调系统及其它需要调节流量的液体管路系统。由于该阀上还设有流量测压小阀,可用智能仪表进行一次性调试,将系统中总水量控制在合理范围内,达到管网平衡,因而节约能源显著。
流量平衡阀,静态流量平衡阀作用
丹富斯静态平衡阀特点
1.线性流量特性,开度大时流量大,开度小时流量小;
2.阀体采用直流式结构,流体阻力小;"
3.有开启百分比显示,开启圈数与阀杆螺距的乘积,即为开度数值;
4.阀门进出口有测压小阀,与智能仪表用软管连接后,可以方便地测量出阀门前后的压差和通过阀门的流量;
5.密封面采用聚四氟乙烯,密封性能好,寿命长。
丹富斯技术参数
工作压力:PN16 温度范围:0-120℃
连接:法兰PN16 流量误差:从*开度到50%开度±5%
丹富斯结构及外形尺寸
DN | D | L | Hmax |
32 | 100 | 185 | 275 |
40 | 110 | 205 | 275 |
50 | 125 | 235 | 305 |
65 | 145 | 295 | 345 |
80 | 160 | 315 | 395 |
100 | 180 | 355 | 430 |
125 | 210 | 400 | 283 |
150 | 240 | 480 | 285 |
200 | 295 | 600 | 467 |
250 | 355 | 730 | 480 |
300 | 410 | 850 | 515 |
350 | 470 | 980 | 1035 |
Dan fuss static balancing valve product overview
Static balancing valve is liquid pipe flow regulating valve, its role is convenient and accurate flow adjustment, effectively solve the uneven and that exist in the pipe network system, hydraulic disorder problem. It not only has the good regulation performance, and has the opening of the opening of the display and function, widely used in heating and air conditioning system and other need to adjust the flow of liquid pipeline system. Because the valve on the flow pressure also has small valve, smart meters available for one-off debugging, the system of total quantity control in the reasonable scope, a balanced network, thus save energy significantly.
Static balancing valve
Dan rich characteristics of static balance valve
1. The linear flow characteristic, large flow, large opening opening hour traffic small;
2. The valve body adopts once-through structure, fluid resistance is small; "
3. There are open, according to the percentage opening laps of the stem and the product of the pitch, the is the opening value;
4. The valve has a small pressure valve, import and export and inligent instrument with a hose connection, you can easily measure the valve before and after the differential pressure across the valve and discharge;
5. Sealing surface using ptfe, sealed performance is good, long service life.
Dan fuss technical parameters
Job stress: PN16 temperature range: 0-120 ℃
Error: connection: flange PN16 flow of the opening of the opening from * to 50% plus or minus 5%
Dan fuss structure and overall dimensions
DN | D | L | Hmax |
32 | 100 | 185 | 275 |
40 | 110 | 205 | 275 |
50 | 125 | 235 | 305 |
65 | 145 | 295 | 345 |
80 | 160 | 315 | 395 |
100 | 180 | 355 | 430 |
125 | 210 | 400 | 283 |
150 | 240 | 480 | 285 |
200 | 295 | 600 | 467 |
250 | 355 | 730 | 480 |
300 | 410 | 850 | 515 |
350 | 470 | 980 | 1035
|